Fairbanks 6020 Series Titan Motor Truck Scale User Manual

Page 9

Advertising
background image

C.

Setting the Modules

1.

Preparing The Modules For Lifting

The module(s) are complete with channel pieces welded to the sides for

attaching lifting hooks. No lifting bolts are required.

2.

Setting the Center or Base Module:

a.

The center or base module is always set first. The center or base module will

have four (4) load cells to install; all other modules will have two (2) load cells.

The modules must be placed in the proper order and aligned in the foundation

so that all modules fit correctly.

b.

These scales HAVE a definite orientation because of the junction box mounts

are welded to one (1) side only. The junction box mount side of the base

module should face the conduit of the main interface / homerun cable.

c.

Place the safety blocks under the modules, which will set the modules at a

height slightly lower than the finished height.

d.

Lift the center or base module to a location above the four load cell base plates.