Fairbanks HVX Series TALON SERIES Motor Truck Scale User Manual

Page 12

Advertising
background image

g.

Hydraulic jacks -- Use hydraulic jacks that have sufficient capacity plus (+) a

safety factor for the model of scale you are installing.

Steel modules

10 ton hydraulic jacks (2)

Field pour Modules

30 ton hydraulic jacks (2)

93296

30 ton jacks

93297

Hand pump

93298

Hose, 6’

h. 100' steel tape measure

i.

Stringline and / or chalkline

j.

Prybars

k.

Grease and anti-seize

l.

Load cell locating tools, one for each load cell,

Part No. 71717 for 5½"

Part No. 107118 for 6"

m. 4" x 4" x 12' timbers for field pour models

2. Foundation

Before installing any part of the scale, the foundation must be checked for accuracy
using Foundation Inspection, Field Check List, FF-2267 / 101732 (see Appendix I).

a.

Layout and position the base plates in the proper locations using the Methods &
Procedures and Certified prints. Each base plate must be level and in full
contact with the top of the pier. Adjustments can be made by chipping the
concrete or grouting under the base plates.

b. Re-check the locations of each base plate against the Certified prints.

Insert two ½" roll pins into each lower cup for anti-rotation.

c.

For 5½" and 6" cell cups, grease and install the inner "O" ring in each cup if
they are not already installed. On all cups, grease the large outer "O" rings,
then install one in the groove on the outside of each cup. Put a

3

/

16

" shim on

the lower cups, grease the outsides, then insert them into the base plates.
Lower cups for 5½" or 6” load cells have a pin which must be aligned between
the two roll pins in the base plate.

d.

Place the upper cup with greased "O" ring on the edge of the the upper
foundation next to each base plate.

e.

Place the load cell locating tool next to each base plate.

50785

12

04/12 Rev. 5

Advertising
This manual is related to the following products: