Fairbanks HVX Series TALON SERIES Motor Truck Scale User Manual

Page 22

Advertising
background image

A. Balance Box 21912, Installation for Analog Indicators

1.

Introduction: Balance box 21912 is intended to be installed at the platform, one box

per section.

2.

Description: Each Stainless Steel balance box has four (4) terminal blocks to

connect two (2) load cells and two (2) cables for connection to the analog

instrument. Load cells and sections are adjusted by means of adjusting

potentiometers.

3.

Installation:

a.

Boxes: The box has tabs for bolting to mounting brackets on the side of the

modules.

Attach the ground wire lug to one of the mounting bolt studs.

Tighten securely to provide a good electrical ground.

b. Wiring: Cable used in all wiring must be a minimum of 18 AWG.

Use cable 17204 or equivalent. The balance boxes are interconnected from

TB4 to TB3 beginning at the end section where the interface cable conduit

enters the scale. An alternate method if the conduit enters the scale in the

middle is to use 14478 Instrument SVP. This will allow separate connections to

go in each direction toward the ends of the scale. See Bulletin 50513 for the

wiring diagrams.

50785

22

04/12 Rev. 5

Section 4: Electrical Installation

Balance box detail

Advertising
This manual is related to the following products: