Fairbanks HVX Series TALON SERIES Motor Truck Scale User Manual

Page 24

Advertising
background image

3.

Box to Instrument:

Terminal

TB2

1

(-) EXC

2

(+) EXC

3

(+) SENSE

4

(-) SENSE

6

SHIELD

7

(+) SIG

8

(-) SIG

4.

Indicator Cable Connection, Balance Box

The two (2) cables from the two (2) center section boxes will enter the 14478

Instrument SVP and terminate there. The cable from the indicator will connect at

14478 Instrument SVP as well. Prepare the cable ends in the standard manner.

Use Appendix II for wiring instructions of all pit balance boxes. Connect the indicator

interface cable to the instrument in the scale house per the instructions in the

appropriate indicator service manual.

50785

24

04/12 Rev. 5

Note: The Full Electronic scales have been designed to provide protection from the effects

of moisture. The load cells have been calibrated with the cable attached and

therefore the cable should NOT be cut. The cable is connected directly to the

balance box or SSC through a sealed bushing which MUST be tightened properly to

keep water/moisture out of the box. All cabling should have a drip loop at the cell or

box entry location to help prevent water entry. On all boxes, particularly stainless

steel, the black plastic fittings have "O" rings that can be forced out of position if the

bushing itself is not tight. To prevent this, first tighten the inner nut securing the

bushing in the hole, then insert cable and carefully tighten the gland until it is very

snug. Do not over-tighten where bushing turns. Secure the cover.

Note: Balance Boxes must have one (1) ground rod in the pit for proper grounding.

~Caution~

Inadequate grounding will prevent the surge voltage protection from functioning properly.