Fairbanks HVX Series TALON SERIES Motor Truck Scale User Manual

Page 18

Advertising
background image

d.

For 5½” or 6” load cells the bottom of the cell has two flatsides which must be

aligned with the flats in the lower cup. Carefully lower the scale (hydraulic

jacks) while seating the bottom of the cell into the lower cup. Check the scale's

level and height, particularly at the approaches. Use the load cell shims

provided to adjust load cell cups for correct height and to ensure that all cells

share an equal amount of the load. Center section cells will have up to twice

the deadload of end section cells.

e.

Once satisfied with height and level, tighten the module-to-module bolts.

The nuts should be torqued to 500 ft lbs.

f.

Load cell cables

Introduction: Cable protection on truck scales is extremely important to the

reliability of the scale. It is imperative for all cables to be installed off of the

ground and out of sight. The Talon truck scale has been designed to

accommodate this type of cable protection. Described in this section is the

manufacturer’s recommended installation procedure for installing and protecting

cables on the Talon Truck Scale.

Cable Hangers: Behind every SSC or PPS mounting block is a cable hanger.

These cable hangers are used to hang excess load cell and interconnecting

cables (see Figure 50785-3).

50785

18

04/12 Rev. 5

50785-3

Advertising