Maintenance
Recommended maintenance schedule

The recommended maintenance schedule depends upon the
nature of the fluid being pumped and the specific application
If the pump is used on a clean fluid, it is recommended that the
pump be removed from service and examined after six months
of operation or after 2,000 hours of operation If the pump is
used on fluids with solids, high temperatures or other items that
could cause accelerated wear this initial examination should be
sooner

After the initial examination of the internal components and wear
items are measured, a specific maintenance schedule can be
determined For best results, it is recommended that the pump
be removed from service annually for examination

Section V - Disassembly

Tools Required:

3/8” Allen wrench or ballpoint hex socket, 3/16” Allen wrench,
(2) flat head screw drivers, 10 mm hex socket, metric socket set
(for pumps with IEC outer drives)

WARNING: Rotating Parts This pump has components that

rotate while in operation Follow local safety standards for

locking out the motor from the power supply during mainte-

nance or service

WARNING: Chemical Hazard This pump is used for trans-
ferring many types of potentially dangerous chemicals

Always wear protective clothing, eye protection and follow

standard safety procedures when handling corrosive or per-

sonally harmful materials Proper procedures should be

followed for draining and decontaminating the pump before

disassembly and inspection of the pump There may be

small quantities of chemicals present during inspection

WARNING: Magnetic force hazard This pump should only

be disassembled and assembled using the recommended

procedures The magnetic attraction is powerful enough to

rapidly pull the motor end and the wet end together Do not

place fingers between the mating surfaces of the motor and

wet ends to avoid injuries Keep the drive magnet and

impeller assembly away from metal chips or particles

1 Stop the pump, lock out the motor starter, close all the

valves that are connected to the pump, and drain/decon-

taminate the pump

WARNING: The pump must be thoroughly flushed of any

hazardous materials and all internal pressure relieved prior

to opening the pump Allow the pump to reach ambient

temperatures prior to performing maintenance

2 Place the pump/motor on the floor with the pump facing

up Remove (4) 1/2” socket head cap screws, lock washers

and flat washers (items 18, 19,

20) securing the pump to the motor Use 3/8” Allen wrench

or 3/8” hex socket on universal joint

3 Firmly grab the motor adapter and pull straight up to disen-

gage the motor and pump See figure 10

For 182, 184, 213, and 215TC motor frame pumps, make

sure the o-ring (item 12B) does not fall out of the motor

adapter (motor end)

4 Place pump on bench with housing (item 1) facing up Using

a 10 mm hex (Allen) wrench, remove (10) M12 socket head

cap screws, lock washers and flat washers (items 15, 16,

17) See figure 11

Figure 10

Figure 11

Remove the housing (item 1) by carefully inserting two flat

head screwdrivers at the locations shown in Figure 12 Slide

the screwdrivers in at the bolt holes between the metal mot-

or adapter and the housing until they stop

Figure 12