2. Installation
35
٧
Flat Type L15SS, L15SM
The actuator base is equipped with T-shaped grooves at the back for installation. Use the T-shaped
grooves on the base and the enclosed nuts for installation. Also, pay attention so the tip of a bolt
would not touch the bottom of the T-shaped groove.
There are also reamed holes for accepting positioning pins.
115
Widened slit for
easy T-nut insertion
Widened slit for
easy T-nut insertion
Reamed Hole [mm]
I
4H10, depth 6mm
[Packaged T-nut]
Maker
Model No.
Material
Surface Treatment
Weight
: SUS
: SFB-008
: S10C or equiv.
: Unichrome plating
: Approx. 14g/pc
M5
17
9
3
17
9.8
10.2
20.2
5
7
About Tightening Screws
• Use a hex socket head cap bolt for the attachment to the base.
• It is recommended to use high-tensile bolts with ISO-10.9 or more.
• Make sure to have the effective length of bolt engagement described below or more for the
tightening of a bolt and a female screw.
When female screw is on steel ĺ Thread length same as nominal diameter
When female screw is on aluminum ĺ Thread length 1.8 times longer them nominal diameter
Caution: Pay special attention when selecting the bolt length. In case that an inappropriate
length of a bolt is applied, it may cause damage on the tapped holes or insufficiency
in attachment strength, which may result in a drop in the operation accuracy or an
unexpected accident.