Troubleshooting, 1 encoder open error (error code: d12) – IAI America LSA-L15SS User Manual

Page 51

Advertising
background image

5.

Troubleshooting

45

5. Troubleshooting

If the actuator has experienced an encoder open error, driver overload error, deviation overflow

error or any other error, check the procedures explained below before concluding that the robot or

controller is faulty. If the problem persists after the applicable measures have been taken, contact

IAI with the detailed condition.

5.1 Encoder Open Error (Error Code: D12)

Encoder open error

Connector wiring

problem?

Dust on the linear scale?

Broken cable?

Faulty controller?

If the problem has not yet

been resolved at this point,

contact IAI.

If you have a spare

controller, swap it with

the current controller and

check the operation.

1) The connector is not properly engaged.

2) The pins are loose.

3) The connected axis numbers are wrong.

(The motor and encoder connectors are

installed in the wrong positions.)

Yes

Clean the linear scale using a dry cloth and

alcohol.

Yes

Replace the broken cable.

Yes

Replace the controller.

Yes

No

No

No

No

Advertising