Chapter 4 Parameters

151

[8] Minimum emergency deceleration (extension motion control board common parameter No. 3)

No.

Parameter name

Unit

Input range

Default value

(reference)

3

Minimum emergency deceleration

G

1~999

30

This parameter sets the minimum deceleration (G) at emergently decelerating and stopping

(emergency stop).

[9] Maximum jog speed when home return not completed (extension motion control board common

parameter No. 4)

No.

Parameter name

Unit

Input range

Default value

(reference)

4

Maximum jog speed when home return not

completed

mm/sec

1~250

30

This parameter sets the maximum jog speed (mm/sec) when home return has not been completed.

[10] Channel usage (extension motion control board input channel parameter, etc.)

No.

Parameter name

Unit

Input range

Default value

(reference)

1

Channel usage

-

0~2

0

This parameter sets how input channels are used.



0: Not used

Input channels are not used.



1: Command pulse input at synchronization operation

Used as the main axis of synchronization electronic cam operation or electronic shaft operation.



2: General-purpose pulse input

Used as a general-purpose input channel.

[11] Pulse input mode (extension motion control board input channel parameter No. 2)

No.

Parameter name

Unit

Input range

Default value

(reference)

2

Pulse input mode

-

0~2

1

This parameter sets pulse input form

(Fixed to negative logic).



0: A/B phase pulse train



1: Pulse train + sign



2: Forward/backward rotation pulse train