6 positioner function – IAI America XSEL-S User Manual

Page 94

Advertising
background image

Chapter 2 Operations

86

2.6 Positioner Function

In addition to the electronic CAM and electronic shaft functions, positioning using position data is

provided, allowing PTP, linear interpolation move, etc.

This operation uses the expansion motion board axis actuator control command to operate. For

details, refer to 3.3.4, "Expansion Motion Board Axis Actuator Control Declaration Command."

2.6.1 Position Data Count

Position data is stored in the user data-hold memory

*1

within the main CPU board and specifies the

number of position data using parameter No. 530 in the range from 1 to 512. Due to limited capacity

of the user data-hold memory, the number of positions stored decreases as the number of effective

axes increases (see Table 2.6.1). Moreover, since the data share the areas with the position data of

the RC gateway function, the number of position data also decreases if the RC gateway function

already uses the position data (see Table 2.6.2). If extension motion control boards use the position

data, the number of position data that can be used by the RC gateway function decreases.

Used Axis Number

Extension Motion Control Board Axis

Position Data Max Number

1 ~ 8

512

9

455

10

409

11

372

12

341

13

315

14

292

15

273

16

256

Table 2.6.1 Used Axis Number and Position Data Max Number

RC Gateway Function Used

Position Number (when 16 axis use)

Extension Motion Control Board Axis

Position Data Max Number

(when 16 axis use)

0

256

64

192

128

128

192

64

256

0

Table 2.6.2 RC Gateway Function Used Position Number and

Extension Motion Control Board Axis Position Data Max Number

*1 User data-hold memory

It is a general-purpose memory area, where data is maintained by battery (the size is 64 KB).