Handling Precautions

1. Precautions on Wiring

[1] It should be handled according to the operation manual for the XSEL-P/Q or R/S controller and

RC controller. Make sure to implement countermeasures against noise for electric devices sharing

the same power supply or within the same equipment.

[2] RC controllers shall be connected to the same 24-VDC power as a general rule. Our PS24

products can be connected in parallel, but if commercially available DC power supply units are to

be used, connect each controller’s power supply to common ground (0 V).

[3] Wire the emergency stop to the X-SEL-P/Q controller and each RC controller in the same system

such that the emergency stop signal is input to the X-SEL-P/Q controller and each RC controller at

the same time.

If a command from the X-SEL controller enters in the emergency stop status on the RC controller

side only when the servo is turned on, the error No. 458 "Pulse train driver servo OFF error during

pulse I/O board axis servo ON” occurs.