1.6 Wiring Method

1.6.1 Connecting X-SEL P/Q to SCON-C/SCON-CA

XSEL-P/Q

x

The following pulse train inputs are connected for each axis.

Example: Connecting to channel 0

X-SEL-P/Q side

SCON-C/CA side

No.

Line

color

I/O

Channel No.

Signal name

Signal name

Line color

1

Blue

Out

Pulse output phase A, + side

Pulse train connector 3 (PP)

Red

2 Orange Out

Pulse output phase A, - side

Pulse train connector 4 (/PP)

White/red

3

Green

Out

Pulse output phase B, + side

Pulse train connector 5 (NP)

Green

4

Brown

Out

0

Pulse output phase B, - side

Pulse train connector 6 (/NP) White/green

* Refer to section 1.7.1 “Pulse Train Cables” for assignment of other channels.

x

The following I/Os are connected for each axis.

Servo ON status (SV)

* I/O assignment on the X-SEL side is performed using parameters (see Section 2.3.2).

Direction

X-SEL-P/Q side

Signal name

SCON-C/CA side

General-purpose input

SV (Servo ON status)

PIO connector 2B

Red-3

General-purpose input

INP (Position complete status)

PIO connector 3B

Orange-3

General-purpose input

HEND (Home return completion status)

PIO connector 4B

Yellow-3

General-purpose input

ALM (Alarm status)

PIO connector 6B

Blue-3

Input

General-purpose input

RMDS (Operation mode status)

PIO connector 8B

Gray-3

General-purpose output SON (Servo ON command)

PIO connector 5A

Green-1

General-purpose output HOME (Home return command)

PIO connector 7A

Purple-1

Output

General-purpose output RES (Alarm reset)

PIO connector 6A

Blue-1

Pulse train control service cable

CB-SC-PIOS………

(Option)

1

2

O

N

ω

ADRS

PIO Cable

CB-X-PIO……… With connector on one side only

CB-X-PIO………-H6 With connectors on both sides

CB-X-PIOH……… With connector on one side only

Toggle the piano switch on the controller’s front panel

to the pulse train mode. Turn the power supply off

and turn SW1 ON (turn over to the left).

SCON

Connector terminal block conversion unit

The customer shall provide the unit.

* The connector can be disconnected and

normal terminal blocks can be used.

(ex. OMRON – Model:XW2D-50G6)