IAI America PCON-ABU User Manual
Page 42
Advertising

24
5.2.2
Absolute Reset from the PC Software
x ACON or PCON
(1) Supply the main power (24 VDC) to the controller and simple absolute unit.
(2) Bring the PC software online to communicate with the controller (connect the controller and PC using
a dedicated communication cable).
(3) Select the MANU operation mode.
Select teaching mode 1 or teaching mode 2.
(4) A “0EE: Absolute encoder error (2)” generates.
(5) Select
Yes (Y).
(6) Click
Position (T), select Edit/Teach (E) [1], select the applicable axis number [2], and then click OK
[3].
[2]
[3]
[1]
Advertising
This manual is related to the following products: