6.3 Alarms, Causes and Actions

(1) Alarms relating to the simple absolute unit (ACON, PCON)

Code Error

Cause/action

Alarm

reset

0B6 Phase-Z

detection
timeout

Cause:
Phase Z could not be detected within the phase-Z output period of
the simple absolute unit.
[1] When the detail code is “H’0001”

Pole sensing + magnetic pole check

[2] When the detail code is “H’0002”

Operation after reversing, following home return and
push-motion operation

Action:
• Check the wiring condition of the motor relay cable.
• Check the wiring condition of brake cable, and turn on/off the

brake reset switch to see if “click” sound is heard.

• Check if the mechanical parts are properly assembled.
• Move the actuator away from the mechanical end and reconnect

the power.

• If the load is normal, turn off the power and try moving it manually

to check the slide resistance.

{

Operation-

cancellation

level

0E5 Encoder

receive error

Cause:
[1] The controller is powered up before the simple absolute unit

when the 24-V power supply is turned on.

[2] When the detail code is “H’0001”

The simple absolute unit cannot communicate properly due to
noise, etc.

[3] When the detail code is “H’0002”

The controller cannot communicate properly with the simple
absolute unit because the communication line in the encoder
cable is disconnected.

Action:
[1] Make sure the simple absolute unit is powered up before (or

simultaneously with) the controller.

[2] Change the installation location of the controller. Implement

noise measures such as installing a FG, noise filter, clamp filter,
etc.

[3] Check the connectors on the encoder relay cable between the

controller and simple absolute unit for looseness. Or, replace
the cable.

X

Cold-start

level

0E8 Phase

A/B

open
detection

0E9 Phase

A

open

detection

0EA Phase

B

open

detection

Encoder signals cannot be detected properly.
Cause:
[1] The connectors on the encoder relay cable are loose or

disconnected.

[2] Piano switch 4 is set wrongly.

Action:
[1] Check the connectors for looseness and disconnection.
[2] Check the switch setting by referring to 5.1.1, “Piano Switch

Settings.”