Function group 1 – run/stop mode – KB Electronics KBDA-42 User Manual

Page 34

Advertising
background image

33

Function

No.

Description

Range/Code

Factory

Setting

1.00*

Run/Stop-Forward/Reverse Control

0000: Keypad

0001: External Contacts

(1)

0002: Communication

(2)

0000

1.01*

Forward/Reverse Control

0000: Instant Reverse
0001: Stop Command Must be Given

Prior to Reverse Command

0002: Reverse Command Disabled
0003: Forward Command Disabled

0000

1.02*

Motor Direction

0000: Forward
0001: Reverse

0000

1.03*

Start Command

0000: Accelerates to Last Set Frequency
0001: Accelerates to Lower Frequency Limit

(See Function No. 3.01)

0000

1.04*

Start Mode

0000: Spin Start
0001: Stop Before Restart

0000

1.05*

Auto/Manual Start Mode

0000: Manual Start Mode
0001: Manual Start with Ride-Through

(Set by Function No. 1.06)

0002: Auto Start After Undervoltage Fault Clears

0003: Auto Start All Faults (Except Short Circuit Fault)

(3)

0004: Auto Start All Faults

(Except I2t , I•t, and Short Circuit Faults)

0000

1.06*

Ride-Through Time (Seconds)

0.0 – 2.0

0.5

1.07*

Number of Restart Attempts

0 – 10

3

1.08*

Auto Start Delay Time (Seconds)

0 – 240

0

1.09*

Stop Mode

0000: Regenerate-to-Stop
0001: Coast-to-Stop
0002: Regeneration with Injection Brake-to-Stop

(Set by Function Nos. 1.11 – 1.13)

0000

1.10*

Holding Torque in Stop Mode (%)

0 – 10

1

1.11

*

Injection Brake Start Frequency (Hz)

0.00 – 240.0

0.00

1.12

*

Injection Brake Level (%)

0 – 30

0

1.13

*

Injection Brake Time (Seconds)

0.0 – 25.5

0.0

FUNCTION GROUP 1 – RUN/STOP MODE

Notes: (1) IODA Option Board required. (2) DIAC Option Board required. (3) For Auto Start, Function No. 1.07 must be set to greater than “0”.

* Functions which can only be changed while the drive is in the Stop Mode.

Advertising
This manual is related to the following products: