KB Electronics KBDA-42 User Manual

Page 40

Advertising
background image

39

FUNCTION GROUP 10 – COMMUNICATION MODE
(DIAC OPTION BOARD REQUIRED) (Continued)

** Read only.

Function

No.

Description

Range/Code

Factory

Setting

10.04

Drive Status

0

0: Stop
1: Run

1

0: Forward
1: Reverse

2

0: Normal
1: Fault

3

0: JOG-LCL/REM Command Off
1: JOG-LCL/REM Command On

4

0: N/A
1: Preset Frequency 1

5

0: N/A
1: Preset Frequency 2

6

0: N/A
1: Preset Frequency 3

7

0: N/A
1: Preset Frequency 4

8

0: N/A
1: Preset Frequency 5

9

0: N/A
1: Preset Frequency 6

10

0: N/A
1: Preset Frequency 7

11

0: Jog Momentary Mode
1: Jog Latching Mode

12

Reserved

13

0: Local
1: Remote

14, 15

Reserved

10.05

Drive Status Description

00

Normal Operation

01

Short Circuit Trip

02

Current Limit

03

Current Limit Trip

04

Undervoltage Trip

05

Recovered Undervoltage Trip

06

Overvoltage Trip

07

Recovered Overvoltage Trip

08

Stop Mode

09

Flash Error

10

External Fault Trip (IODA)

11

IODA Error

12

Phase Loss Trip

13

Current Source Trip (IODA)

10.06 **

Communications Error Count

10.07 **

Motor Voltage

10.08 **

Motor Current

10.09 **

Bus Voltage

10.10 **

Motor Frequency