KB Electronics KBIC-240DS User Manual

Page 10

Advertising
background image

10

TABLE 5. GENERAL PERFORMANCE SPECIFICATIONS

Speed Range (ratio)

50:1

Load Regulation (% base speed) (0 - full load; 50:1 speed range)

1 *

Line Voltage Regulation (% base speed at full load; 100 - 130 VAC)

1/2 *

Control Linearity (% speed vs. dial rotation)

2

CL/Torque Range (% full load).

0 - 300

ACCEL Time Period (0 - full speed) (seconds)

0.5 - 4.0

MIN Speed Trimpot Range (% full speed)

0 – 30 *

MAX Speed Trimpot Range (% full speed)

50 – 140 *

IR Compensation Trimpot Range (at specified full load) (volts)

0 - 24

Maximum Allowable Ambient Temperature at full rating (º C/º F)

45/113

Maximum Inrush Start Current (Peak DC amps)

3 times CL Setting

Note: * Performance is for the SCR rated PM motors only. Lower performance can be expected with
other motor types. Factory setting is for 3% load regulation. To obtain superior regulation. See
Section 7, paragraph 7.5 on page 19.

Advertising
This manual is related to the following products: