TABLE 1. FIELD CONNECTIONS (SHUNT-WOUND MOTORS ONLY)

AC LINE

VOLTAGE

FIELD VOLTAGE

(VDC)

FIELD

CONNECTION

FIELD TYPE

115

100

F+, F-

Full Voltage

115

50

F+, L1

Half Voltage

230

200

F+, F-

Full Voltage

CAUTION

Shunt-wound motors may be
damaged if field remains energized
with the motor stopped for an
extended period of time, unless
provided with external cooling.

230

100

F+, L1

Half Voltage

TABLE 2. ELECTRICAL RATINGS

RATING WITHOUT

AUXILLARY HEAT SINK

RATING WITH

AUXILLARY HEAT SINK

Model

No.

Part

No.

AC

Line

Voltage

(VAC)

+/- 15%

50/60

Hz

Motor

Voltage

(VDC)

(3)

Max.

AC

Load

Current

(RMS

Amps)

Max.

DC

Load

Current

(Avg.

Amps)

Max.

HP

Max.

AC

Load

Current

(RMS

Amps)

Max.

DC

Load

Current

(Avg.

Amps)

Max.

HP

Field

Voltage

(Shunt

Wound

Motor

Only)

(VDC)

KBIC-

120

9429

115

0 – 90

9.0

6.0

0.5

18.0

12.0

1

50, 100

KBIC-

125

9433

115

0 – 90

12.0

8.0

0.75

24.0

16.0

1.5

50, 100

KBIC-

240

9428

208/230

0 – 180

9.0

6.0

1

18.0

12.0

2

100, 200

KBIC-

225

9432

208/230

0 – 180

12.0

8.0

1.5

24.0

16.0

3

100, 200

115

0 – 90

0.5

1

50, 100

KBIC-

240D

(1)

9464

208/230

0 – 180

9.0 6.0

1

18.0

12.0

2

100, 200

KBIC-

240DS

(2)

9423

115,

208/230

0 – 90

9.0

6.0

0.5

18.0

12.0

1

100

Notes: (1) Model KBIC-240D is designed to accept 115 or 230 VAC line input to provide 0 - 130 VDC with a 115
or 230 VAC line and 0 - 220 VDC with a 208/230 VAC line. (2) Model KBIC-240DS is designed to accept 115 or
208/230 VAC line input to provide 0-130 VDC with a 115 or 208/230 VAC line. (3) A higher output voltage can
be reached by increasing MAX trimpot setting.