WARNING! 1.THE INHIBIT CIRCUIT TERMINALS ("I1" AND "I2") IS NEVER TO BE USED AS A

SAFETY DISCONNECT SINCE IT IS NOT FAIL-SAFE. USE ONLY THE AC LINE FOR THIS
PURPOSE. 2. DO NOT DISCONNECT AND RECONNECT THE MOTOR ARMATURE WITH THE AC
LINE APPLIED OR CATASTROPHIC FAILURE WILL RESULT. SEE ARMATURE SWITCHING
(DYNAMIC BRAKING), ON PAGE 20.

9.3 Leader/Follower Connections - The KBIC

®

can be used with the KBSI

®

to drive multiple motors. Refer to

Figure 10.

FIGURE 10. LEADER / FOLLOWER

CONNECT

AS ABOVE

KBSI-

240D

** Connect the high side of the

potentiometer to the terminal
"P" ( QD).

(a) SINGLE MAIN POTENTIOMETER

5K
POT

KBIC

MAIN MOTOR

ADDITIONAL

FOLLOWER *

KBIC

FOLLOWER
MOTOR #3

ISOLATION DIODE

KBIC

RATIO
5K OHM

KBIC

FOLLOWER
MOTOR #1

FOLLOWER
MOTOR #2

* A 10K ratio potentiometer is used to control

up to (10) "Follower" motors. If a 5K ratio potentiometer
is used, up to (5) "Follower" motors can be used.

1. Multiple KBIC controls should be powered from the same
phase AC line.

2. The positive output terminal to each speed,
must be installed with a 1A-600PIV isolation diode.

(b) SINGLE MAIN MOTOR

KBSI-

240D

R