0 programming the sm-basic drive – LEESON SM-Basic Series Sub-Micro Inverters (Obsolete) User Manual

Page 22

Advertising
background image

18

Press

Mode to enter password

Use

s and t to scroll to the

password value

13.0

PROGRAMMING THE SM-Basic DRIVE

The drive may be programmed by one of two methods: using the three buttons and 2-digit LED
display on the front of the drive, or programming the Electronic Programming Module (EPM) using
the optional EPM Programmer. This section describes programming the drive using the buttons and
display, which are shown below:

To enter the PROGRAM mode to access the parameters, press the

Mode button. This will activate

the PASSWORD prompt (if the password has not been disabled). The display will read “00” and the
upper right-hand decimal point will be blinking, as shown below:

Use the

s and t buttons to scroll to the password value (the factory default password is “25”) and

press the

Mode button. Once the correct password value is entered, the display will read "01", which

indicates that the PROGRAM mode has been accessed at the beginning of the parameter menu (01 is
the first parameter), and the upper right decimal point will turn on solid. This is shown below:

Parameter menu is accessed at the
first parameter

BUTTONS

Press

Mode

Right decimal point blinks

Display reads "00"

DISPLAY

Mode

Upper right decimal point turns on solid.