19

NOTE: If the display flashes “Er”, the password was incorrect, and the process to enter the password
must be repeated.

Use the

s and t buttons to scroll to the desired parameter number. In the example below, Parameter

19 is being displayed, which is the ACCELERATION TIME of the drive:

Once the desired parameter number is found, press the

Mode button to display the present parameter

setting. The upper right-hand decimal point will begin blinking, indicating that the present parameter
setting is being displayed, and that it can be changed by using the

s and t buttons.

Use

s and t to change setting

(example setting changed to 30)

Press

Mode to store new setting

Pressing the

Mode will store the new setting and also exit the PROGRAM mode. To change another

parameter, press the

Mode key again to re-enter the PROGRAM mode (the parameter menu will be

accessed at the parameter that was last viewed or changed before exiting). If the

Mode key is pressed

within two minutes of exiting the PROGRAM mode, the password is not required access the parameters.
After two minutes, the password must be entered in order to access the parameters again.

Use

s and t to scroll to the desired

parameter number

Press

Mode to display present parameter

setting (present example setting is 15)

Right decimal point blinks