8

Installation

Connections

Assumptions: This drive series supplies motor voltage
from its A1 and A2 terminals. It is assumed throughout this
manual that when A1 is positive with respect to A2, the
motor will rotate clockwise (CW) while looking at the output
shaft protuding from the front of the motor. If this is
opposite of the desired rotation, simply reverse the wiring to
the motor from A1 and A2.

INHIBIT SWITCH

(optional)

10K

SPD ADJ

POT

CW

LINE VOLTAGE

115 VAC

MOTOR

L1

L2

A1

A2

S3

S2

S1

H2

H1

STOP

RUN

Figure 5. Drive Connections