Torque (cont.) – LEESON Chassis Mount PWM Control: M1740009.00 User Manual

Page 22

Advertising
background image

16

Calibration

3. Lock the motor armature. Be sure that the motor is firmly

mounted.

4. Connect power to the drive. The motor should remain

stopped.

5. Set the speed adjust potentiometer to maximum (full CW).

6. Adjust the TORQUE trimpot CW slowly until the armature

current is 120% of motor rated armature current.

7. Set the speed adjust potentiometer to minimum and

remove power from the drive.

8. Remove the stall from the motor.

TORQUE (cont.)

TORQUE

1/4 HP
130 VDC
2500 RPM
1.40 ADC

1/8 HP
90 VDC
1800 RPM
1.30 ADC

1/8 HP
130 VDC
2500 RPM
1.00 ADC

IR COMP

TORQUE

IR COMP

TORQUE

IR COMP

TORQUE

1/10 HP
90 VDC
1725 RPM
1.10 ADC

1/15 HP
90 VDC
1800 RPM
0.75 ADC

1/20 HP
90 VDC
1750 RPM
0.56 ADC

IR COMP

TORQUE

IR COMP

TORQUE

IR COMP

Figure 10. Typical TORQUE and IR COMP Settings

(actual settings may vary with each application)

Advertising