17

S3

S2

S1

R1

R2

R4

TOTAL SERIES

RESISTANCE

10K OHMS

R3

Figure 11. Multiple Fixed Speeds

Replace the speed adjust potentiometer with series
resistors with a total series resistance of 10K ohms
(Figure 11). Add a single pole, multi-position switch with the
correct number of positions for the desired number of fixed
speeds.