Application Notes

Multiple Fixed Speeds

Replace the speed adjust potentiometer with series resistors
with a total series resistance of 10K ohms (Figure 10). Add a
single-pole, multi-position switch with the correct number of
positions for the desired number of fixed speeds.

S0502

S3

S2

S1

R4

R3

R1

TOTAL SERIES

RESISTANCE

10K OHMS

R2

SO502 3-PIN HEADER

Use customer supplied

Molex connector #09-50-3031 to mate

with 3-pin header (SO502) on control board.

Figure 10. Multiple Fixed Speeds