Application Notes

RUN/JOG switch

Using a RUN/JOG switch is recommended in applications where
quick stopping is not needed and frequent jogging is required.
Use a single pole, two position switch for the RUN/JOG switch,
and a single pole, normally closed, momentary operated
pushbutton for the JOG pushbutton.

RUN/JOG option #1

In the first wiring option, connect the RUN/JOG switch and JOG
pushbutton to the inhibit plug as shown in Figure 13. The motor
coasts to minimum speed when the RUN/JOG switch is set to
JOG. Press the JOG pushbutton to jog the motor. Return the
RUN/JOG switch to RUN for normal operation.

JOG

RUN

JOG

PUSHBUTTON

INHIBIT

SO501 2-PIN HEADER

Use LEESON accessory plug harness

(part number: 900282.01) to mate

with 2-pin header (SO501) on control board.

Figure 13. RUN/JOG Switch Option #1