background image

1

SPEEDMASTER™ OPERATION MANUAL

Specifications

Max.

Armature

HP Range

HP Range

Current

with 115 VAC

with 230 VAC

Model

(Amps DC)

Applied

Applied

Style

174102

10.0

1/8–1

1/4–2

NEMA 4X

174103

10.0

1/8–1

1/4–2

NEMA 4X

174107

10.0

1/8–1

1/4–2

NEMA 4X

AC Line Voltage

115 VAC or 230 VAC ±10%, 50/60 Hz, single phase

Armature Voltage (115 VAC Input)

0–90 VDC

Armature Voltage (230 VAC Input)

0–180 VDC

Form Factor

1.37 at base speed

Field Voltage (115 VAC Input)

50 VDC (F1 to L1); 100 VDC (F1 to F2)

Field Voltage (230 VAC Input)

100 VDC (F1 to L1); 200 VDC (F1 to F2)

Max. Field Current

1 ADC

Accel. Time Range:

for 0–90 VDC Armature Voltage

1 – 15 seconds

for 0–180 VDC Armature Voltage

1 – 15 seconds

**Analog Input Voltage Range (signal must be isolated; S1 to S2):

for 0–90 VDC Armature Voltage

0 – 1.4 VDC

for 0–180 VDC Armature Voltage

0 – 2.8 VDC

Decel. Time Range:

for 0-90 VDC Armature Voltage

1 – 15 seconds

for 0–180 VDC Armature Voltage

1 – 15 seconds

Current Limit Range:

for 0–90 VDC Armature Voltage

0 – 14 A

for 0–180 VDC Armature Voltage

0 – 13.5 A

Input Impedance (S1 to S2)

3M ohms

Load Regulation

1% base speed or better

Vibration

1G max (0–50 Hz)

Ambient Temp. Range (cased drive)

10°C–40°C

**Does not Apply to 174103