Multiple fixed speeds

Replace the speed adjust potentiometer with series resistors

with a total series resistance of 10K ohms (Figure 14). Add a

single pole, multi-position switch with the correct number of

positions for the desired number of fixed speeds.

Figure 14. Multiple Fixed Speeds

S3

S2

S1

R1

R2

R4

TOTAL SERIES

RESISTANCE

10K OHMS

R3