Troubleshooting

5. Motor is not connected.

1. MIN SPD and MAX

SPD settings are too
high.

1. MIN SPD and MAX

SPD are not calibrated.

1. MAX SPD setting is too

low.

2. IR COMP setting is too

low.

3. Motor is overloaded.

1. IR COMP is set too

high.

2. Control is in current

limit mode.

5. Connect motor to A1

and A2.

1. Recalibrate MIN SPD

and MAX SPD.

1. Recalibrate MIN SPD

and MAX SPD

1. Increase MAX SPD

setting.

2. Increase IR COMP

setting.

3. Check motor load.

Resize the motor and
drive if necessary.

1. Adjust the IR COMP

setting slightly CCW
until the motor speed
stabilizes.

2. Check that motor and

drive are of sufficient
horsepower and
amperage.

Line fuse does not blow,
but the motor does not run
(cont.)

Motor runs too fast at
maximum speed setting

Motor runs too slow or
too fast

Motor will not reach the
desired speed.

Motor pulsates or surges
under load.

Symptom

Possible

Causes

Suggested

Solutions