Symptom possible causes suggested solutions – LEESON Chassis Mount PWM Control: 175292.00 User Manual

Page 40

Advertising
background image

34

Troubleshooting

Line fuse blows

Line fuse does not blow,
but the motor does not run

1. Line fuses are the wrong

size.

2. Motor cable or armature

is shorted to ground.

3. Nuisance tripping caused

by a combination of
ambient conditions and
high-current spikes.

1. Speed adjust pot or

reference voltage is set
to zero speed.

2. Speed adjust pot or

reference voltage
connections are open.

3. Drive is overloaded.

4. Drive is not receiving

DC line voltage.

1. Check that line fuses

are the correct size.

2. Check motor cable and

armature for shorts.

3. Add a blower to cool
the drive components;
decrease CUR LIMIT
settings, or resize motor
and drive for actual load
demand, or check for
incorrectly aligned
mechanical components
for “jams”. See page 25
for information on
adjusting the CUR LIMIT
trimpot.

1. Increase speed adjust

pot or reference voltage
setting.

2. Check that the speed

adjust pot or reference
voltage connections are
not open.

3. Verify that the motor is

not jammed. Increase
CURR LIMIT setting.

4. Apply DC line voltage

to +VDC and -VDC.

Symptom

Possible

Causes

Suggested

Solutions