Warning, Electrical connections, Solar installation – American Water Heater 317994-002 User Manual

Page 18

Advertising
background image

18

A diaphragm-type expansion tank suitable for potable

water will normally eliminate this weeping condition.

Please read and follow the manufacturer’s instructions for

the installation of such tanks.

MASSACHUSETTS CODE

DOES NOT ALLOW THIS

TYPE OF INSTALLATION.

Must Be Vertical To

Remove Air Bubbles

Domestic

Hot Water

Out

Mixing

Valve

Hot

Water

Out

Unions

To Air

Handler

Vacuum

Relief

Valve

Expansion Tank

Cold Water Inlet

Flow Control

Pump

Valve

In

Out

Coil

Air

Handler

Shut-Off

Valve

Typical Mixing Valve Installation Combination

Space Heating/Potable Water Heating System

FIGURE 16

Electrical Connections

Before plugging in the water heater, always make sure:

The Voltage and frequency correspond to that specified

on the water heater.

The electrical outlet has the proper overload fuse or

breaker

protection.

Unit is to connect to a 120VAC electrical supply outlet

(extension cord is not allowed).

IMPORTANT: Do not use an extension cord to connect the

water heater to an electrical outlet.

The water heater and the outlet are properly grounded.

Installed in accordance with prevailing provisions of

local codes, or in the absence of such, National Electric

Code, ANSI/NFPS 70 current edition.

Completely fill the tank with water and check all con-

nections for leaks. Open the nearest hot water faucet and

let it run for three (3) minutes to purge the water lines of

air and sediment and to ensure complete filling of the tank.

The Electrical power may then be turned on. Verify proper

operation after servicing.

WARNING

Electric Shock Hazard

Disconnect power before
servicing.

Replace all parts and panels
before operating.

Failure to do so can result in
death or electrical shock.

Pressure
Switch

Control Display

Power Supply
Transformer

Igniter/Flame
Sense Connector

Air Intake
Chamber Fan

Anode
Rod

Gas Control
Valve / Thermostat

CAUTION:

LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.

FV

Sensor

CAUTION:

DO NOT USE AN EXTENSION
CORD TO CONNECT THE
TRANSFORMER TO AN
ELECTRICAL OUTLET.

Also see Water System Piping for additional instructions on

the safe and correct installation and operation of this water

heater.

Solar Installation

If this water heater is used as a solar storage heater
or as a backup for the solar system, the water supply
temperatures to the water heater tank may be in excess of
120°F. A mixing valve or other temperature limiting valve
must be installed in the water supply line to limit the supply
temperature to 120°F.
NOTE: Solar water heating systems can often supply
water with temperatures exceeding 180°F and may result
in water heater malfunction.

Wiring Diagram