Warning – American Water Heater 317994-002 User Manual

Page 7

Advertising
background image

7

Location Requirements

Carbon Monoxide Poisoning Hazard

WARNING

Do not install in a mobile home.

Doing so can result in carbon monoxide poisoning and death.

The FVIR System is designed to reduce the risk of

flammable vapor-related fires. Flammable liquids (such as

gasoline, solvents, propane, etc,) emit flammable vapors

which can be ignited by a gas water heater’s hot surface

igniter or main burner. The resulting flashback and fire can

cause death or serious burns to anyone in the area.

This heater is equipped with a FV sensor for detecting the

presence of flammable vapors. When the sensor detects

those vapors, the unit will shut down and not operate.

Should this happen, please refer to the troubleshooting

guide on pages 31-32 (numbers 9,11,12). Even though this

water heater is a flammable vapors ignition resistant water

heater and is designed to reduce the chances of flamm-

able vapors being ignited, gasoline and other flammable

substances should never be stored or used in the same

vicinity or area containing a gas water heater or other open

flame or spark producing appliance.

WARNING

Flammable Vapors

FLAMMABLES

Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other
appliance. Storage of or use of gasoline or other
flammable vapors or liquids in the vicinity of this or
any other appliance can result in serious injury or
death.

Read and follow water heater warnings and
instructions

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

Do not use or store flammable products such as gasoline,

solvents, or adhesives in the same room or area near the

water heater. If such flammables must be used, all gas

burning appliances in the vicinity must be shut off and their

pilot lights extinguished. Open the doors and windows for

ventilation while flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in

the area of the water heater, leave the area immediately

and call the fire department from a neighbor’s home. Do

not attempt to clean the spill until all ignition sources have

been extinguished.

Fire or Explosion Hazard

WARNING

• Read instruction manual before installing, using or
servicing water heater.

• Improper use may result in fire or explosion.

• Maintain required clearances to combustibles.

Keep combustibles such as boxes, magazines, clothes, etc. away
from the water heater area.

Site Location

Select a location near the center of the water piping

system. The water heater must be installed indoors

and in a vertical position on a level surface. DO NOT

install in bathrooms, bedrooms, or any occupied room

normally kept closed.

Locate the water heater as close to the chimney or gas

vent as practical. Consider the vent system piping and

combustion air supply requirements when selecting the

water heater location. The venting system must be able

to run from the water heater to termination with minimal

length and elbows.

Locate the water heater near the existing gas piping.

If installing a new gas line, locate the water heater to

minimize the pipe length and elbows.

The water heater should be located in an area not

subject to freezing temperatures. Water heaters

located in unconditioned spaces (i.e., attics,

basements, etc.) may require insulation of the water

piping and drain piping to protect against freezing.

The drain and controls must be easily accessible for

operation and service. Maintain proper clearances as

specified on the water heater.

Do not locate the water heater near an air-moving

device. The operation of air-moving devices such

as exhaust fans, ventilation systems, clothes dryers,

fireplaces, etc., can affect the proper operation of the

water heater. Special attention must be given to condi-

tions these devices may create. Flow reversal of flue

gases may cause an increase of carbon monoxide

inside of the dwelling (Figure 1).

The water heater is to be located as close as possible

to a 120VAC outlet. NOTE: all electrical wiring should

be in accordance to the NEC and all local/state

electrical codes (extension cord is not allowed).


NOTE: This water heater must be installed according to all

local and state codes or, in the absence of local and state

codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA

54)-current edition and the “National Electrical Code”, ANSI/

NFPS 70 current edition.

FV Sensor

FIGURE 1A.

Advertising