Troubleshooting flowchart – American Water Heater 317994-002 User Manual

Page 33

Advertising
background image

33

Please Note:

The control continually monitors
internal circuits and external sensors.
Error codes noted above, and those for
self-diagnostic faults can be found on
pages 30 through 32.

APPLY POWER TO

APPLIANCE

YES

REQUEST

FOR HEAT

PRESENT?

NO

IS

PRESSURE SWITCH

PROVEN OPEN WITHIN

5

SECONDS?

NO

COMBUSTION

FAN ON

YES

IS

PRESSURE SWITCH

PROVEN CLOSED

WITHIN

5

SECONDS?

NO

WAIT FOR PRESSURE

SWITCH TO OPEN

DISPLAY ERROR

NUMBER

7

WAIT FOR PRESSURE

SWITCH TO CLOSE

DISPLAY ERROR

NUMBER

6

PREPURGE

IS

IGNITOR

OKAY?

TURN OFF

COMBUSTION FAN,

DISPLAY ERROR CODE

NUMBER

8

NO

IGNITOR ON FOR

WARM-UP TIME

YES

GAS VALVE OPENS

MAIN

BURNER LIGHTS

AND IS SENSED

DURING TRIAL

FOR

IGNITION

IGNITOR TURNS OFF

YES

NO

IS

FLAME SENSE

LOST?

IS

REQUEST FOR HEAT

SATISFIED?

GAS VALVE OFF

COMBUSTION FAN

OFF AFTER POST-

PURGE DELAY

GAS VALVE CLOSES

LESS

THAN

3

TRIES

FOR IGNITION?

GAS VALVE CLOSES

LOST

LESS THAN

4

TIMES?

YES

YES

TURN OFF

COMBUSTION FAN

AFTER POST-PURGE

DISPLAY ERROR

3

ONE HOUR

AUTOMATIC RESTART

TIME DELAY

NO

NO

NO

YES

YES

NO

IS

PRESSURE SWITCH

PROVEN OPEN WITHIN

5

SECONDS?

WAIT FOR PRESSURE

SWITCH TO OPEN

DISPLAY ERROR

NUMBER

7

INTERPURGE

COMBUSTION

FAN OFF

YES

NO

YES

COMBUSTION FAN

OFF

COMBUSTION FAN

ON

3 MINUTE

AUTOMATIC RESET

TIME DELAY

IS

PRESSURE SWITCH

PROVEN CLOSED

WITHIN

5

SECONDS?

WAIT FOR PRESSURE

SWITCH TO CLOSE

DISPLAY ERROR

NUMBER

6

NO

YES

IS

PRESSURE SWITCH

PROVEN CLOSED

WITHIN

5

SECONDS?

WAIT FOR PRESSURE

SWITCH TO CLOSE

DISPLAY ERROR

NUMBER

6

YES

NO

TROUBLESHOOTING FLOWCHART