Powered Anode Operation
To protect the glass-lined water tank from corrosion
through electrolysis, this water heater is equipped with a
non sacrificial powered anode rod. The powered anode
rod is non sacrificial and should not need to be replaced
unless damaged.
If the powered anode rod has been damaged then the
powered anode rod should be removed and replaced
from the water heater tank. IMPORTANT: If the damaged
powered anode rod has not been replaced but has been
remove permanently, this will void any warranties.

FIGURE 22.

NOTE: Whether re-installing or replacing the powered
anode rod, check for any leaks and immediately correct if
found.

In replacing the power anode:
1. Turn off electrical supply and gas supply to the water

heater.

2. Shut off the water supply and open a nearby hot water

faucet to depressurize the water tank.

3. Drain approximately 5 gallons of water from tank

(Refer to the “Draining and Flushing” section for proper
procedures). Close drain valve.

4. Remove the wiring connection on the top of the

powered anode rod and remove the old powered
anode rod (Figure 22).

5. Use

Teflon

®

tape or approved pipe sealant on threads

and install new anode rod.

6. Turn on water supply and open nearby hot water faucet

to purge air from water system. Check for any leaks
and immediately correct any if found.

7. Turn on electrical and gas supplies. Restart the water

heater as directed under the “Operating Your Water
Heater.” See the “Repair Parts Illustration” section for
anode rod location.

TEFLON

®

is a registered trademark of E.I. Du Pont De Nemours and Company

Draining and Flushing

It is recommended that the tank be drained and flushed

every 6 months to remove sediment which may build up

during operation. The water heater should be drained if

being shut down during freezing temperatures. To drain the

tank, perform the following steps:
1. Turn off the gas to the water heater at the manual gas

shut-off valve and turn off the electrical power to the

gas control/thermostat valve.

2. Open a nearby hot water faucet until the water is not

longer hot.

3. Close the cold water inlet valve.
4. Connect a hose to the drain valve and terminate it to

an adequate drain or external to the building.

5. Open the water heater drain valve and allow all the

water to drain from the tank. Flush the tank with water

as needed to remove sediment.

6. Close the drain valve, refill the tank, and restart the

heater as directed in this manual.

If the water heater is going to be shut down for an

extended period, the drain valve should be left open.
IMPORTANT: Condensation may occur when refilling the

tank and should not be confused with a tank leak.

Routine Preventive Maintenance

At least annually, a visual inspection should be made of

the venting and air supply system, piping systems, and

main burner. Check the water heater for the following:

Obstructions, damage, or deterioration in the venting

system. Make sure the ventilation and combustion air

supplies are not obstructed.

Clean any dust or debris from the louvers of the air

intake chamber.

Soot and/or carbon on the main burner. Contact a

qualified technician.

Leaking or damaged water and gas piping.

Presence of flammable or corrosive materials in the

installation area.

Presence of combustible materials near the water

heater.

After servicing this water heater, check to make sure

it is working properly. (See “Operating Your Water

Heater” section of this manual.)

IMPORTANT: If you lack the necessary skills required to

properly perform this visual inspection, you should not

proceed, but get help from a qualified technician.

Powered

Anode

Rod

Powered Anode System

To ensure a long, trouble-free

operating life, this water

heater is equipped with a

powered anode system.

The powered anode rod is of

a permanent design and does

not need replacing unless

damaged.