properly. To prevent water damage, the valve must be pro-

perly connected to a discharge line which terminates at an

adequate drain. Standing clear of the outlet (discharged

water may be hot), slowly lift and release the lever handle

on the temperature and pressure relief valve to allow the

valve to operate freely and return to its closed position.

See Figure 23. If the valve fails to completely reset and

continues to release water, immediately shut off the

manual gas control valve and the cold water inlet valve

and call a qualified technician.

TEMPERATURE AND PRESSURE
RELIEF VALVE

DISCHARGE LINE TO DRAIN

MANUAL RELIEF
VALVE

FIGURE 23.

FIGURE 24.

Removing the Burner from the Manifold/
Burner Assembly

Natural Gas Burner

1. Take off the burner by removing the two (2) screws

located underneath the burner.

2. Check the burner to see if it is dirty or clogged. The burner

may be cleaned with soap and hot water (Figure 25).

FIGURE 25.

Replacement Parts

IMPORTANT: The following maintenance procedures are

for the FVIR System components and should be performed

by a qualified technician.
Replacement parts may be ordered through your plumber

or the local distributor. Parts will be shipped at prevailing

prices and billed accordingly. When ordering replacement

parts, always have the following information ready:
1. model, serial, and product number

2. type of gas

3. item

number

4. parts

description

See Repair Parts Section for a list of available repair parts.

Removing the Manifold/Burner Assembly

1. Turn off the gas supply to the water heater at the manual

gas shut-off valve. This valve is typically located beside

the water heater. Note the position of the shut-off valve in

the open/on position then proceed to turn it off (Figure 3).

2. Disconnect power supply to the heater.
3. Remove the outer door. Remove the 2 screw securing

the manifold door assembly to the skirt.

4. Disconnect all wiring connectors from the gas control

valve/thermostat (Figure 24). Disconnect the manifold

tube at the gas control valve/thermostat.

5. Grasp the manifold tube and push down slightly to free

the manifold from the gas control valve/thermostat.

6. Carefully remove the manifold assembly from the burner

compartment. NOTE: Be sure not to damage internal

parts (Figure 28).

7. Check the burner to see if it is dirty or clogged. The

burner may be cleaned with soap and hot water.

Temperature and Pressure Relief Valve

Explosion Harzard

• Temperature-pressure relief

valve must comply with ANSI
Z21.22-CSA 4.4 and ASME
code.

• Properly sized temperature-

pressure relief valve must be
installed in opening provided.

• Can result in overheating

and excessive tank pressure.

• Can cause serious injury or

death.

Manually operate the temperature and pressure relief

valve at least once a year to make sure it is working

MAINTENANCE OF YOUR WATER HEATER

Manifold Tube

Control Display,
Anode Rod
Connector

Pressure
Switch / Fan,
FV Sensor
Connector

Power Supply
Transformer
Connector

Igniter/Flame
Sense
Connector

Gas Control Valve/
Thermostat

Burner

(Bottom View)

Screws

Manifold Door Assembly

Igniter/Flame

Sense Connector

View Port

Advertising