Warning, Checking the draft, Water heater operation – American Water Heater 317994-002 User Manual

Page 21: Burn hazard

Advertising
background image

21

MATCH

RELIEF

OPENING

DRAFT HOOD

FIGURE 18.

If the flame flutters or is blown out, combustion products are

escaping from the relief opening. If this occurs, do not operate

the water heater until proper adjustments or repairs are made

to the vent pipe system and/or air supply requirements.

Checking the Draft

WARNING

Burn Hazard

Do not touch vent.

Doing so can result in burns.

After successfully lighting the water heater, allow the unit to

operate for 15 minutes and check the draft hood relief

opening for proper draft (Figure 18). Make sure all other

appliances in the area are operating and all doors are closed

when performing the draft test. Pass a match flame around

the relief opening of the draft hood. A steady flame drawn

into the opening indicates proper draft.

Water Heater Operation

Figure 17 below shows the water heater’s sequence of

operation when a call for heat is initiated. The ignition

control module will attempt to light the burner three times.

If the ignition control does not detect ignition it will enter

lockout mode, indicated by display flashing status code
(see status code 3 page 30 and/or status code 9 page 31).

FIGURE 17.

Sequence of Operation

CALL FOR

HEAT INDICATED

BY FLASHING OF

DISPLAY SCREEN

STATUS CODES

CONTROL CHECKS TO ENSURE

PRESSURE SWITCH IS OPEN

DRAFT BLOWER IS ENERGIZED

CONTROL CHECKS TO ENSURE

PRESSURE SWITCH IS CLOSED,

INDICATING BLOWER OPERATING

AND THERE ARE NO VENTING

BLOCKAGES (INLET OR OUTLET)

CONTROL ENERGIZES HOT

SURFACE IGNITER (HSI)

MAIN VALVE ENERGIZES ALLOW-

ING THE BURNER TO BE LIT BY

HSI, DRAFT BLOWER ENERGIZES

FLAME SENSE ROD DETECTS

FLAME OF MAIN BURNER

WATER IN TANK IS HEATED BY

MAIN BURNER AND

TEMPERATURE REACHES

THERMOSTAT SETTING

MAIN VALVE DE-ENERGIZES

AND BLOWER CONTINUES FOR

A POST PURGE TIME

HEATER RETURNS TO

STANDBY MODE

MAIN VALVE DE-ENERGIZES

AND DRAFT BLOWER CONTINUES

FOR A POST PURGE TIME OF

APPROX. 30 SECONDS