American Water Heater 317994-002 User Manual

Page 27

Advertising
background image

27

3. Insert the manifold/burner assembly into the burner

compartment making sure that the tip of the manifold
tube engages in the slot of the bracket inside the
combustion chamber (Figure 29).

4. Inspect the door gasket and make sure there is no

fiberglass insulation between the gasket and the
combustion chamber.

5. Replace the two screws, which secure the manifold/

burner assembly door to the combustion chamber
and tighten securely. Once the manifold/burner
assembly door is tightened, visually inspect the door
gasket between the manifold/burner assembly door
and the combustion chamber for spaces or gaps that
would prevent a seal. IMPORTANT: Do not operate
the water heater if the door gasket does not create a
seal between the manifold door and the combustion
chamber.

6. During the following procedure, do not cross-thread

or apply any thread sealant to any of the fittings listed

below. First, reconnect the manifold tubing to the gas
control valve/thermostat.

7. Reconnect the flame sense/hot surface igniter wire to

the gas control valve/thermostat (Figure 24).

8. Turn gas supply on and refer to the Lighting

Instructions.

9. With the burner lit, check the gas control valve/

thermostat supply line, two piece wire connector, and

manifold tube connections for leaks. Check for leaks by

brushing on an approved noncorrosive leak detection

solution. IMPORTANT: Do Not splash solution onto
the electrical connections.
Bubbles forming indicate

a leak. Correct any leak found. All leaks must be fixed
immediately.

10. Replace the outer door (see item K page 5).

Door Gasket

Viewport

Manifold Tab

Slot

Burner

FIGURE 29.

Removing and Replacing the Gas Control
Valve/Thermostat

IMPORTANT: Use only factory authorized replacement

parts.
Removing the Gas Control Valve/Thermostat:
1. Set the gas control valve/thermostat to its lowest setting

by first depressing the COOLER and HOTTER

buttons together and hold for 1 second. Then press the

COOLER button until the lowest setting appears

(Figure 21).

2. Unplug the electrical transformer from the wall outlet.

3. Turn off the gas supply to the water heater at the

manual gas shut-off valve. This valve is typically located

beside the water heater. Note the position of the shut-

off valve in the open/on position then proceed to turn it

off (Figure 3).

4. Drain the water heater. Refer to the section of

“Draining and Flushing” section and follow the

procedure.

5. Disconnect the the flame sense/hot surface igniter

wire, power supply transformer, pressure switch/

fan and display connector wires from the thermostat

(Figure 24). Disconnect the manifould tube at the

thermostat (Figure 24).

6. Refer to “Gas Piping” section (Figure 3) and disconnect

the ground joint union in the gas piping. Disconnect the

remaining pipe from the gas control valve/thermostat.

7. To remove the gas control valve/thermostat, thread a

correctly sized pipe into the inlet and use it to turn the gas

control valve/thermostat (counterclockwise.) Do not use

pipe wrench or equivalent to grip body. Damage may

result, causing leaks. Do not insert any sharp objects into

the inlet or outlet connections. Damage to the gas control

valve/thermostat may result.

Replacing the Gas Valve:
1. To replace the gas control valve/thermostat,

reassemble in reverse order. When replacing the gas

control valve/ thermostat, thread a correctly sized

pipe into the inlet and use it to turn the gas valve

(clockwise.) DO NOT OVER TIGHTEN or damage may

result. NOTE: Use an approved

TEFLON

®

tape or pipe

compound only on the threaded section of the gas

control valve/thermostat that screws into the tank.

2. Reconnect the gas piping to the gas control valve/

thermostat. NOTE: Use an approved Teflon tape or

pipe compound on the gas piping connections.

3. Reconnect the manifold tube, flame sense/hot surface

igniter wire, power supply transformer, pressure switch/

fan and display connector wires (Figure 24).

4. Fill the tank completely with water. NOTE: To purge the

lines of any excess air, keep the hot water faucet open

for 3 minutes after a constant flow of water is obtained.

5. Turn on the gas supply and test the gas supply

connections by brushing on an approved noncorrosive

leak detection solution. IMPORTANT: Do Not splash

solution onto the electrical connections. Bubbles

forming indicate a leak. Correct any leak found.

6. Check the operation of the burner by following the

lighting instructions on the front of the water heater.

With the burner lit, check the gas control valve/

thermostat supply line, manifold tube connections for

leaks.

7. Verify proper operation and then replace the outer door.
8. If additional information is required, contact Residential

Technical Assistance by referencing the phone number on

the water heater or on the front cover of this manual.