7.7. Matrix Control Connections

All drivers, associated software and extra documentation are available on the B-500-MTRX-230 product page at www.

SnapAV.com under the Support Tab.

7.7.1. IR Control

The B-500-MTRX-230 can be controlled by IR flasher from the front panel receiver or by

attaching a mono cable from the control system flasher output to the “System IR In” port on the

back of the matrix switcher. For the most reliable control, use the System IR In port.

The matrix switcher can also be controlled by commands received on IR Receiver inputs from

connected B-500-RX-230-IR HDBaseT Receivers. (See Section 7.10.2. IR Pass-Through from Rooms to Sources on

page 17 for an application example of this feature.)
Note: System IR control, front panel IR Receiver and Matrix control from Room can be disabled when not in use by

using the Configuration Utility. See the Configuration Utility manual section, “Other Settings” for more information.

7.7.2. RS232 Control

To control the B-500-MTRX-230 with RS232, the devices must use the correct pin configuration for the control system

in use.

The matrix switcher receives control data on pin 2 (RxD – Data Receive) and transmits control data on pin 3

(TxD - Data Transmit). The connection cable between the matrix switcher and the Automation System will need

to be configured so that pin 2 (RxD) on the switcher is connected to the control system TxD pin, and pin 3 (TxD)

on the switcher is connected to the control system RxD (Receive Data) pin. See the diagram below for details.

Configuration for control system serial ports can vary. Refer to the documentation for the system in use to ensure

proper connection and configuration.

Note: This port is also used to communicate with a PC when using the PC Configuration Utility. Refer to the

Configuration Utility manual for details.

7.7.3. Ethernet/IP Control

The B-500-MTRX-230 includes an Ethernet port that can be used to control the device using Telnet Protocol. This port

follows TIA 568 A/B standards; please refer to these standards when terminating cables.

To configure the matrix switcher for use with the driver, it will be necessary to connect the unit to a PC and access it

with the Matrix Configuration Utility. See the Configuration Utility manual and the IP driver documentation for complete

setup instructions.

B-500-MTRX-230 RS232 Port Configuration

LINK

LINK

PWR

LINK

LINK

LINK

LINK

LINK

LINK

Engineered in the USA

Manufactured in Taiwan

IR IN ALL IR OUT

DB9 Female Connector

RxD (Data Receive)
TxD (Data Transmit)
GND

Pin

Function

2

RxD (Data Receive)

3

TxD (Data Transmit)

5

Ground/Common