Rear panel – Staub Electronics B-500-MTRX-230-8X16 BINARY - HDMI 8X16 MATRIX SWITCH WITH HDMI AND HDBASET OUTPUTS User Manual

Page 7

Advertising
background image

B-500-MTRX-230 Installation Manual

Pg. 7

www.snapav.com Support: 866.838.5052

6.2. Rear Panel

1. Ethernet Port

RJ45 port for connecting an Ethernet Cat5e/6 cable for IP control of the B-500-MTRX-230.

2. System All IR Out

3.5mm mono mini port, repeats all IR commands from all connected HDBaseT outputs (from IR Receiver port of

B-500-RX-230-IR).

3. System IR In

3.5mm mono mini IR input port for matrix control.

4. HDBaseT Outputs 1 through 16 (RJ45)

Connect 568B terminated Cat5e/6 HDBaseT cable routed to a B-500-RX-230-IR to feed HDMI signal to display.

Output simultaneously displays the same source as the HDMI output of the same number. Odd numbered outputs

are at the top and even numbered outputs are at the bottom.

5. HDMI Outputs 1 through 16

Connect HDMI cables to route to displays. Output simultaneously displays the same source as the HDBaseT output

of the same number. Odd numbered outputs are at the top and even numbered outputs are at the bottom.

6. Output Number Legend

Printed diagram to indicate output numbering.

7. HDMI Inputs 1 through 8 (or 16)

Connect HDMI cables from sources to the matrix switcher for distribution. Odd numbered outputs are at the top and

even numbered outputs are at the bottom.

8. IR Output to Source 1 through 8 (or 16)

Blue 3.5mm mono mini ports are used to connect IR flashers for controlling sources. These ports may be set to

route commands only from the IR output corresponding to the HDBaseT output number (IR zone routing), or directly

to the source selected on an HDBaseT output (IR source routing). Odd numbered outputs are at the top and even

numbered outputs are at the bottom. See Section 9.1. IR Source Routing on page 22 for routing setup.

9. IR Input to Room

Green 3.5mm mono mini ports are used to route IR commands to the B-500-RX-230-IR IR Flasher port connected

to each respective output. Use these connections to control displays or other equipment from the matrix location.

Odd numbered outputs are at the top and even numbered outputs are at the bottom.

10. Redundant Power Jacks

Dual polarized, 12V DC 11.25A power connections. Connect the power supply on whichever side is more convenient.

11. USB Port

Reserved for future use.

12. RS-232 Control (DB9)

Attach connection from control system or Windows PC for serial control of the B-500-MTRX-230. Update firmware

on the matrix switcher.

13. USB/RS232 Toggle Switch

USB firmware update switch for main board updates. Must be set to RS232 for normal operation.

14. Input Number Legend

Printed diagram to indicate input and IR connection numbering.

12V DC 11.2A

INPUT

IR INPUT

TO ROOM

IR INPUT

TO ROOM

IR OUTPUT

TO SOURCE

IR OUTPUT

TO SOURCE

1
2

3
4

5
6

7
8

9

10

11
12

13
14

15
16

O

1
2

3
4

5
6

7
8

9

10

11
12

13
14

15
16

UTPUTS

12V DC 11.2A

INPUT

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

O

N

1 2 3

4

5

7

10 11 12 13

6

14

8

9

10

Advertising