Step 3

Select the Piconet tab.

The following dialog box will open showing factory default settings. Merlin
defaults to “Page Sync & Record." This setting tells Merlin to

perform a General

Inquiry and then collect sync information from the specified slave device when the slave
responds. Merlin then waits for the Master to begin paging the Slave devices. When paging
begins, Merlin synchronizes to the Master and begins recording.

For this recording, leave most of these settings unchanged. If you are recording a
Hop Frequency that is not 79 Hops Standard, you will need to select the
appropriate standard from the Hop Frequency menu below.

Step 4

Click OK to close the Recording Options window and
activate the recording options you selected.

At this point, Merlin will be ready to record.