Merlin Protocol Analyzer User’s Manual

CATC

SW Version 2.0

Add ...

The Add button lets you add devices to the Configurations List. Clicking
Add causes the following dialog box to open:

Name - Symbolic name for easy identification of the device and connector.

Controller -> Host - COM port used for monitoring the HCI traffic from
the application to the bluetooth baseband.

Host -> Controller - COM port used for monitoring the HCI traffic from
the Bluetooth baseband (Controller) to the application (Host).

Rate - Sets the maximum rate in bits per second (bps) that you want data to
be transmitted through this port.

Data Bits - Changes the number of data bits you want to use for each
character that is transmitted and received. The computer or device you are
communicating with must have the same setting that you choose here. Most
characters are transmitted in seven or eight data bits.

Parity - Changes the type of error checking you want to use for the selected
port. The computer or device you are communicating with must have the
same setting that you choose here. You must choose one of the following:

None - No parity bit will be added to the data bits sent from this
port. This will disable error checking.

Even - Parity bit is set to 1 if it is needed to make the number of
ones in the data bits even. This will enable error checking.

Odd - Parity bit is added if it is needed to make the number of ones
in the data bits odd. This will enable error checking.

Mark - Parity bit is added but is always set to 1.

Stop Bits - Changes the time between each character being transmitted
(where time is measured in bits).