Command List

SCB-1

R

16

Version Check

A special command, which is the only command that does not use the packet-format is 76hex
(ASCII 'v'). If the camera receives this command, it will respond with "SCB-1
Vx.xxx"+CR+LF. This command can be used for easy communication-check with a terminal
program and is also included for compatibility with other WolfVision Products.

Replies from the camera

H L D C Remarks

Command OK:

00

F1

01

0D

reply within max. 0.5s

Illegal Command:

00

F1

10

FE

Command failed:

00

F1

11

FD

Command not possible in the moment

Parameter wrong:

00

F1

12

FC

(or wrong command length)


Checksum Error:

00

F1

20

EE

Timeout Error:

00

F1

21

ED

after the 00-header, the rest of the

command must be sent within 1 sec.

Command to long:

00

F1

22

EC

(Receive Buffer Overflow)



Short Inquiry Reply: 00

Fx

60

R[1]

R[2] ... R[x-1] C

(no Command Ok will be sent)

Long Inquiry Reply: 00

Len H Len L C

60

R[1]

R[2] ... R[Len-1] C

(no Command Ok will be sent)

(all numbers are hex, C=Checksum, H=Header, L=Length, D=Data)

Commands

C=Checksum, P=Position (1 Byte), PH/PL: Position (2Byte) High/Low-Byte, Sp=Speed,
H=Header, L=Length; VL=Value

Commands of Camera, Future

The SCOTI protocols of all WolfVision cameras (stand alone) are almost the same.
Only some commands more or less are supported on other camera-types due to the different
technologies.
In the future (at higher firmware-versions) further commands may be added which are not
supported yet (listed commands are available with v1.03a).