Press the Dial Type softkey to toggle between both
types of dialing modes. Press the Enter softkey to save
the highlighted dial mode and return to the 12 Lead
Monitor menu. If you want to return to the 12 Lead
Monitor menu without saving the highlighted dial mode,
press the Return softkey.

PT Info Softkey

Press the PT Info softkey to access the patient
demographic information.

You can select from the following softkeys: ID#, Age,
Gender, Patient Record or Return.

Note: If no information is entered, the default age of 60

is displayed above the Age softkey and the
default gender of Male is displayed above the
Gender softkey. The 12SL algorithm processes
ECG data based on age. All patients age 41 and
older are handled in the same manner by the
algorithm.

If a patient is under 41 years of age, you must enter the
patient's age. This is especially important because the
12SL algorithm contains age-specific criteria. For
patients 15 years of age or younger, the 12SL algorithm
performs a pediatric analysis.

Patient Identification Number (ID#)

Press the ID # softkey to access the Name and ID#
screen. The cursor goes directly to Patient Name field. If
you don’t want to enter a name, press the ID # softkey to
move the cursor to the Patient ID field. Otherwise, use
the scroll keys on top of the unit to select a character on
the keypad, then press the Commit ( ) key on top of the
unit to enter the character in the Patient Name field.

Repeat for each additional character (up to 14) in the
Patient Name field.

When you have entered the patient name, select the
Enter (

) key from the keypad and press the

Commit ( ) key on top of the unit (or you can press the

Space Bar Key

5HWXUQ

,'

&DQFHO

371$0(-
37,'

Return Softkey to save the information). The highlight
automatically advances to the Patient ID# line.

The Patient ID# characters are entered exactly the same
way as patient name characters above. When the ID# has
been entered, select the Enter (

) key from the keypad

and press the Commit ( ) key on top of the unit to store
the name and ID number and return to the Patient
Information menu (or you can press the Return Softkey to
save the information).

If you do not want to enter a Patient ID#, use the scroll
keys to select the Enter (

) key from the keypad, and

then press the Commit ( ) key. If no patient ID # is
entered, the E Series automatically generates a 12 digit
patient ID# based on the year/date/time (200002151320)
of the first 12-lead acquisition.

Use the Cancel softkey to exit this screen without saving
the information.

Note: Whenever possible, enter a patient identification

number (ID #) before transmitting 12-lead ECG
data to a MUSE system. If the data does not have a
unique ID number, the medical facility must search
through all of its unidentified records to find the
patient's information.

Patient Age

To set the patient age, press the Age softkey, to display
the keypad. Use the scroll keys to select a number, then
press the Commit ( ) key to enter the digit in the Age field
(both scroll keys and the Commit key are on top of the
unit). Repeat for each digit (up to 3 digits). Press the
Return softkey to save the highlighted age and return to
the Patient Information screen.

If you want to return to the Patient Information screen
without saving the age, press the Cancel softkey.

5HWXUQ

,'