Error responses, Using the command and response table, Symbol definitions – Extron Electronics SW HDMI Series User Guide User Manual

Page 26

Advertising
background image

SW HDMI Series • Remote Communication and Control

20

Error Responses

If the switcher is unable to execute a command it receives because the command is invalid
or contains invalid parameters, the switcher returns an error response to the host. The
following error response codes can be sent:

E01

– Invalid input channel number (out of range)

E06

– Invalid input selection during auto-input switching

E10

– Invalid command

E13

– Invalid value (out of range)

Using the Command and Response Table

The

command and response table

, starting on page 22, lists valid ASCII and

hexadecimal command codes, the switcher responses to the host, and a description of the
command function or the results of executing the command.
The conversion table below is for use with the command and response table.

ASCII to Hex Conversion Table

Space

Figure 14.

ASCII to Hex Conversion Table

Symbol Definitions

]

= CR/LF (carriage return with line feed) (hex 0D 0A)

}

= Soft carriage return (no line feed)

= Space

E

= <Escape> key

X!

= Input number

0 through the maximum number of inputs on the unit (2 or 4)

0 = Deselect (mute) all inputs

X@

= Mute on or off

0 = Mute off (unmuted)

1 = Mute on (muted)

X#

= Video color bit depth mode

0 = Automatically truncate based on output

1 = Force truncation to 8-bit

X$

= EDID mode and file selection

0 = Automatic mode (default): EDID of the connected display is detected and passed to
the inputs.

1-46 = Factory-supplied EDID number (For a description of available EDID files, see the

EDID table

” on page 17.)

47-50 = User-assigned EDID

X%

= Current EDID information in hexadecimal format (128 or 256 bytes of hex data)

X^

= Native resolution and refresh rate (translated from hexadecimal)

X&

= Firmware version (to the second decimal place)

Advertising