Error responses, Using the command and response table, Symbol definitions – Extron Electronics SW HDMI Series User Guide User Manual
Page 26

SW HDMI Series • Remote Communication and Control
20
Error Responses
If the switcher is unable to execute a command it receives because the command is invalid
or contains invalid parameters, the switcher returns an error response to the host. The
following error response codes can be sent:
E01
– Invalid input channel number (out of range)
E06
– Invalid input selection during auto-input switching
E10
– Invalid command
E13
– Invalid value (out of range)
Using the Command and Response Table
The
, starting on page 22, lists valid ASCII and
hexadecimal command codes, the switcher responses to the host, and a description of the
command function or the results of executing the command.
The conversion table below is for use with the command and response table.
ASCII to Hex Conversion Table
•
Space
Figure 14.
ASCII to Hex Conversion Table
Symbol Definitions
]
= CR/LF (carriage return with line feed) (hex 0D 0A)
}
= Soft carriage return (no line feed)
•
= Space
E
= <Escape> key
X!
= Input number
0 through the maximum number of inputs on the unit (2 or 4)
0 = Deselect (mute) all inputs
X@
= Mute on or off
0 = Mute off (unmuted)
1 = Mute on (muted)
X#
= Video color bit depth mode
0 = Automatically truncate based on output
1 = Force truncation to 8-bit
X$
= EDID mode and file selection
0 = Automatic mode (default): EDID of the connected display is detected and passed to
the inputs.
1-46 = Factory-supplied EDID number (For a description of available EDID files, see the
“
47-50 = User-assigned EDID
X%
= Current EDID information in hexadecimal format (128 or 256 bytes of hex data)
X^
= Native resolution and refresh rate (translated from hexadecimal)
X&
= Firmware version (to the second decimal place)