Chapter 6 Features

Sensor

Type

Process Error Enable

Calibration Offset

Units

Input Error Latc

hing

Scale Low

Scale HighRange High

Process Error Low

Value

Thermistor Curve

Resistance Range

Filter

Range Low

Clear Latc

h Request

TC Linearization

Analog Input

Off

Analog Input

Displa

y Precision

Analog Input Value

Process Error Enable

Calibration Offset

Units

Input Error Latc

hing

Scale Low

Scale HighRange High

Process Error Low

Value

Filter

Range Low

Clear Latc

h Request

TC Linearization

Analog Input

Thermocouple

Analog Input

Displa

y Precision

Sensor

Type

Sensor

Type

Process Error Enable

Calibration Offset

Units

Input Error Latc

hing

Scale Low

Scale HighRange High

Process Error Low

ValueFilter

Range Low

Clear Latc

h Request

TC Linearization

Analog Input

Process & Potentiometer

Analog Input

Displa

y Precision

Analog Input Value

Calibration Offset

Input Error Latc

hing

Thermistor Curve

Resistance Range

Filter

Clear Latc

h Request

Analog Input

Thermistor

Analog Input

Displa

y Precision

Analog Input Value

Sensor

Type

Process Error Enable

Calibration Offset

Units

Input Error Latc

hing

Scale Low

Scale HighRange High

Process Error Low

Value

Filter

Range Low

Clear Latc

h Request

TC Linearization

Analog Input

RTD

Analog Input

Displa

y Precision

Analog Input Value

Analog Input Value

Input Error

Input Error

Input Error

Input Error

Input Error

Compare Function

An error, when read, can indicate any of the follow-

ing: None, Open, Shorted, Measurement Error, Bad

Cal Data, Ambient Error, RTD Error, Fail, Math Er-

ror, Not Sourced, Stale
Tolerance is expressed in the same units as Source

A. For the function to work properly Source A and

Source B must be without errors.

[`S2;A

] Source Zone A : 0 to 16

[`S2;b]

Source Zone B : 0 to 16

[`Si;A]

Source Instance A : 1 to 250

Compare

Overview

Instances - 16 per RML

Tolerance

Error Handling

Function

[`CPE]

Compare Menu

[`SEt]

Setup Page

[`Si;b]

Source Instance B : 1 to 250

[`Er;h]

Error Handling : False Bad, False Good, True Bad, True Good

[`CPE]

Compare Menu

[oPEr]

Operation Page

[`Su;A]

Source Value A : -1,999.000 to 9,999.000 units or F

[`Su;b]

Source Value B : -1,999.000 to 9,999.000 units or F

[``o;u]

Output Value : Off, On

Output Value

Error

Source Value A

Source Value B

Source Function A
Source Instance A
Source Zone A
Source Error A

Source Function B
Source Instance B
Source Zone B
Source Error B

[`toL]

Tolerance : 0.0 to 9,999.000 units or F

[SFn;a]

Source Function A : None, Analog Input, Current, Cool Power,

Heat Power, Power, Linearization, Math, Process Value, Set Point

Closed, Set Point Open, Variable

[``fn]

Function : Off, Greater Than, Less Than, Equal To, Not Equal

To,

[SFn;b]

Source Function B : None, Analog Input, Current, Cool Power,

Heat Power, Power, Linearization, Math, Process Value, Set Point

Closed, Set Point Open, Variable

No Compare, Output Value = OFF

Tolerance

Error Handling

Function

Output Value

Error

Source Value A

Source Value B

Source Function A

Source Instance A

Source Zone A

Source Error A

Source Function B

Source Instance B

Source Zone B

Source Error B

Compare