3 transmitter mounting, Transmitter mounting -2, Important – Yokogawa EJX118A User Manual

Page 24

Advertising
background image

<4. Installation>

4-2

IM 01C25H01-01E

F0402.ai

50mm minimum

Minimum

liquid level

High

pressure

side

Install the sealed diaphragm

so that the shank positions

downward.

Low

pressure

side

IMPORTANT

The transmitter should be

installed as low as possible

below the position where

the high pressure side

diaphragm seal is installed.

Install the sealed diaphragm

so that the shank positions

downward.

IMPORTANT

Figure 4.2

Installing the Diaphragm Seals to a

Tank

4.3 Transmitter Mounting

■ The transmitter can be mounted on a nominal

50 mm (2-inch) pipe using the mounting

bracket supplied, as shown in Figure 4.3.

The transmitter can be mounted on either a

horizontal or a vertical pipe.

■ When mounting the bracket on the transmitter,

tighten the (four) bolts that hold the transmitter

to a torque of approximately 39 N·m {4 kgf·m}.

F0403.ai

U-bolt nut

Mounting bracket

Mounting bracket

50mm (2-inch) pipe

U-bolt

U-bolt

Horizontal pipe mounting

50mm (2-inch) pipe

Transmitter

mounting bolt

Transmitter

mounting bolt

U-bolt nut

Vertical pipe mounting

Figure 4.3

Transmitter Mounting

IMPORTANT

Never loosen the four bolts securing the cover

flange or the screws at the joints between the

capillary tube and cover flanges (Refer to figure

3.2.) If the seal liquid leaks, the transmitter

cannot be used.