Normal operating condition – Yokogawa EJX118A User Manual

Page 44

Advertising
background image

<8. General Specifications>

8-2

IM 01C25H01-01E

Normal Operating Condition

(Selected features may affect limits.)

Ambient Temperature Limits

–40 to 60°C (–40 to 140°F)

–30 to 60°C (–22 to 140°F) with LCD display

Note: The ambient temperature limits must be within the

fill fluid operating temperature range, see table

8.1.

Process temperature

for fill fluid code B

Process temperature

for fill fluid code A

Process temperature

for fill fluid code C

Flange max.

working

pressure

Atmospheric

pressure

Transmitter ambient

temperature range

(for fill fluid code A, B)

Process Temperature (°C)

Working

pressure

kPa abs

(psi abs)

2.7 (0.38)

100 (14.5)

0.1 (0.014)

1 (0.14)

10 (1.4)

-50 0 50 100 150 200 250 300350

F0801a.ai

Figure 8.1a Working Pressure and Process

Temperature (Fill fluid: silicone oil for

general and high temperature use)

Process Temperature Limits

See table 8.1.

Ambient Humidity Limits

0 to 100% RH

Working Pressure Limits

See table 8.1.

For atmospheric pressure or below, see figure

8.1a through 8.1e.

Table 8.1

Process temperature, Ambient temperature, and Working pressure

Code

Process

temperature

*1

Ambient

temperature

*2

Working pressure

Specific gravity

*3

Silicone oil

(general use)

A

–10 to 250°C

(14 to 482°F)

*4

–10 to 60°C

(14 to 140°F)

2.7 kPa abs

(0.38 psi abs) to flange

rating pressure

1.07

Silicone oil

(general use)

B

–30 to 180°C

(–22 to 356°F)

–15 to 60°C

(–5 to 140°F)

0.94

Silicone oil
(high temperature use)

C

10 to 310°C

(50 to 590°F)

10 to 60°C

(50 to 140°F)

1.09

Fluorinated oil

(oil-prohibited use)

D

–20 to 120°C

(–4 to 248°F)

–10 to 60°C

(14 to 140°F)

51 kPa abs (7.4 psi abs)

to flange rating pressure

1.90 to 1.92

Ethylene glycol

(low temperature use)

E

–50 to 100°C

(–58 to 212 °F)

–40 to 60°C

(–40 to 140°F)

100 kPa abs

(atmospheric pressure) to

flange rating pressure

1.09

Silicone oil

(high temp. and high

vacuum use)

1

–10 to 250°C

*4

(14 to 482°F)

–10 to 60°C

*5

(14 to 140°F)

0.013 kPa abs

(0.0019 psi abs) to flange

rating pressure

1.07

Silicone oil

(high temp. and high

vacuum use)

2

10 to 310°C

(50 to 590°F)

10 to 60°C

*5

(50 to 140°F)

1.09

Silicone oil

(high vacuum use)

4

–10 to 100°C

(14 to 212°F)

–10 to 60°C

*5

(14 to 140°F)

1.07

*1:

See figure 8.1a through 8.1e ‘Working Pressure and

Process Temperature.’

*2:

This ambient temperature is the transmitter ambient

temperature.

*3:

Approximate values at a temperature of 25°C (77°F)

*4:

In case of wetted parts material code TW (Tantalum),

process temperature limit is up to 200°C (392°F).

*5:

The upper ambient temperature limit is 50°C (122°F) in

the following combinations.

Process connection

style code

Process connection

size code

W (Flush type)

2 (2-inch) or

8 (1 1/2-inch)

E (Extension type)

3 (3-inch)

Note: The differential pressure transmitter should be installed

at least 600 mm below the high pressure (HP) process

connection.

However, this value (600 mm) may be affected by ambient

temperature, operating pressure, fill fluid or material of the

wetted diaphragm.

Contact YOKOGAWA when the transmitter can not

be installed at least 600 mm below the HP process

connection.

Advertising