10-8

10. GENERAL SPECIFICATIONS

Item

Description

Code

Painting

Color change

Coating change

Lightning protector

Calibration units

Sealing treatment to
SUS630 nuts

Long vent

P

PR

X1

HC

A

K1

D1

D3

D4

Y

U

(See Table for Span

and Range Limits)

Amplifier cover only

Amplifier cover and terminal cover, Munsell 7.5 R4/14

Epoxy resin-baked coating

Transmitter power supply voltage: 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically safe
type, 9 to 32 V DC for F

OUNDATION

Fieldbus and PROFIBUS PA communication type.)

Allowable current: Max. 6000 A (1

؋40 µs), Repeating 1000 A, 100 times

316 SST exterior parts

Exterior parts on the amplifier housing (name plates, tag plate, zero-adjustment screw,
stopper screw) will become 316 or 316L SST.

Degrease cleansing treatment

P calibration (psi unit)

bar calibration (bar unit)

M calibration (kgf/cm

2

unit)

Sealant (liquid silicone rubber) is coated on surfaces of SUS630 nuts used
for cover flange mounting.

Total vent plug Length: 112 mm (standard, 32 mm), Material: SUS316

Gold-plate

A1

Gold-plated diaphragm

High Accuracy Type

HAC

PE3

High Accuracy (Applicable for Model EJA310A)

European Pressure Equipment
Directive

*2

PED 97/23/EC (Applicable for Model EJA440A)
CATEGORY: III, Module: H, Type of Equipment: Pressure Accessory - Vessel,
Type of Fluid: Liquid and Gas,
Group of Fluid: 1 and 2

K2

Degrease cleansing treatment with fluorinated oil filled capsule.
Operating temperature –20 to 80 °C

Oil-prohibited use

130 Pa abs {1 mmHg abs}

S1

Minimum input pressure: 130 Pa abs{1 mmHg abs} at range calibrating testing

Mill Certificate

Cover flange

Cover flange, Process connector

Test Pressure: 50 kPa{0.5 kgf/cm

2

} Capsule L, M

Test Pressure: 3 MPa{30 kgf/cm

2

} Capsule A

Test Pressure: 14 MPa{140 kgf/cm

2

} Capsule B

Test Pressure: 32 MPa{320 kgf/cm

2

} Capsule C

Test Pressure: 50 MPa{500 kgf/cm

2

} Capsule D

M01

M11

T04

T03

T02

T09

T08

Pressure test/
Leak test Certificate

Nitrogen(N

2

) Gas

*3

Retention time: 10 minutes

K5

Degrease cleansing and dehydrating treatment

K6

Degrease cleansing and dehydrating treatment with fluorinated oilfilled capsule.
Operating temperature –20 to 80 °C

Oil-prohibited use
with dehydrating treatment

Stainless steel
amplifier housing

Amplifier housing material; SCS14A stainless steel (equivalent to SUS316 cast stainless
steel or ASTM CF-8M)

E1

T1010.EPS

Fast response *

4

F1

Updete time: 0.125 sec or less, see GS for response time

Body option

Stainless steel tag plate

N1

N2

N3

N4

Without drain and vent plugs

N1 and Process connection on both sides of cover flange with blind kidney flanges
on back

N1, /N2, and Mill certificate for cover flange, diaphragm, capsule body, and blind
kidney flange

JIS SUS 304 stainless steel tag plate wired onto transmitter

Custom software configuration

Configuration

R1

Failure alarm down-scale *

1

C1

C2

C3

Output status at CPU failure and hardware error is –5%, 3.2 mA or less.

NAMUR NE43 compliant *

1

Output signal limits:
3.8 mA to 20.5 mA

Failure alarm down-scale: output status at CPU failure and
hardware error is –5%, 3.2 mA or less.

Failure alarm up-scale: output status at CPU failure and
hardware error is 110%, 21.6 mA or more.

*1:

Applicable for Output signal code D and E. The hardware error indicates faulty amplifier or
capsule. When combining with Optional code F1, output status for down-scale is –2.5%,
3.6 mA DC or less.

*2:

Lower limit of process temperature is –30

ЊC when Bolts and nuts material code A is selected.

*3:

Applicable for EJA310A and EJA430A. For EJA440A, the test fluid is water or Nitrogen (N

2

)

gas.

*4:

Applicable for Output signal code D and E. Write protection switch is attached for Output code E.