Handling cautions, 1 model and specifications check, 2 unpacking – Yokogawa EJA310A User Manual

Page 9: 3 storage, 4 selecting the installation location, Handling cautions -1, Model and specifications check -1, Unpacking -1, Storage -1, Selecting the installation location -1

Advertising
background image

IM 01C21D01-01E

2-1

2. HANDLING CAUTIONS

2.

HANDLING CAUTIONS

This chapter describes important cautions regarding
how to handle the transmitter. Read carefully before
using the transmitter.

The EJA-A Series pressure transmitters are thoroughly
tested at the factory before shipment. When the
transmitter is delivered, visually check them to make
sure that no damage occurred during shipment.

Also check that all transmitter mounting hardware
shown in Figure 2.1 is included. If the transmitter was
ordered without the mounting bracket or without the
process connector, the transmitter mounting hardware
is not included. After checking the transmitter, repack
it in the way it was delivered until installation.

Bolt

Process connector

Process connector
Gasket

U-bolt nut

U-bolt

Mounting bracket
(L type)

Transmitter mounting bolt

Mounting bracket
(Flat type)

F0201.EPS

Figure 2.1 Transmitter Mounting Hardware

2.1 Model and Specifications

Check

The model name and specifications are indicated on the
name plate attached to the case. If the reverse operat-
ing mode was ordered (reverse signal), ‘REVERSE’
will be inscribed in field *1.

F0202.EPS

: Refer to USER'S MANUAL

Figure 2.2 Name Plate

2.2 Unpacking

When moving the transmitter to the installation site,
keep it in its original packaging. Then, unpack the
transmitter there to avoid damage on the way.

2.3 Storage

The following precautions must be observed when
storing the instrument, especially for a long period.

(a) Select a storage area which meets the following

conditions:
• It is not exposed to rain or water.
• It suffers minimum vibration and shock.
• It has an ambient temperature and relative

humidity within the following ranges.

Ambient temperature:

–40 to 85

°C without integral indicator

–30 to 80

°C with integral indicator

Relative humidity:

5% to 100% R.H. (at 40

°C)

Preferred temperature and humidity:

approx. 25

°C and 65% R.H.

(b) When storing the transmitter, repack it as nearly

as possible to the way it was packed when
delivered from the factory.

(c) If storing a transmitter that has been used,

thoroughly clean the chambers inside the cover
flanges, so that no measured fluid remains in it.
Also make sure before storing that the pressure-
detector and transmitter section are securely
mounted.

2.4 Selecting the Installation

Location

The transmitter is designed to withstand severe
environmental conditions. However, to ensure stable
and accurate operation for years, observe the follow-
ing precautions when selecting an installation loca-
tion.

Advertising
This manual is related to the following products: