Function of the modules, Main module, Input/output modules – Yokogawa PC-Based MX100 User Manual
Page 11

11
IM MX100-0E
Function of the Modules
Main Module
The main module is equipped with a power supply connector, a power switch, an
Ethernet port, a CF card slot, a 7-segment LED, dipswitches and other parts. It contains
functions such as the power supply to and the control of each input/output module,
communications with a PC, data storage to the CF card when communication is
disconnected.
Ethernet port
Power switch
CF card
slot
Power connector
or screw terminal
7-segment LED
Dipswitch*
DATA ACQUISITION UNIT
ETHERNET
POWER
10BASE - T
100BASE - TX
100 - 240V AC
Do not operate without reading safety precaution in users manual.
70VA MAX
50/60Hz
SW
ON
1 2 3 4 5 6 7 8
Functional ground terminal
* Normally, turn all switches ON.
Used to enable the /DS option
functions, initialize settings,
and perform other functions.
1 2 3 4 5 6 7 8
ON
Input/Output Modules
The following twelve types of modules are available.
• 4-CH, High-Speed Universal Input Module (MX110-UNV-H04)
• Minimum measurement interval: 10 ms
• Maximum number of inputs: 4 inputs
• Input types: DC voltage, TC, 3-wire RTD, and DI (LEVEL,
non-voltage contact)
• 10-CH, Medium-Speed Universal Input Module (MX110-UNV-M10)
• Minimum measurement interval: 100 ms
• Maximum number of inputs: 10 inputs
• Input types: DC voltage, TC, 3-wire RTD, and DI (LEVEL,
non-voltage contact)
• 30-CH, Medium-Speed DCV/TC/DI Input Module (MX110-VTD-L30)
• Minimum measurement interval: 500 ms
• Maximum number of inputs: 30 inputs
• Input types: DC voltage, TC, and DI (LEVEL, non-voltage contact)
For MX110-VTD-L30/H3
For MX110-VTD-L30
Function Introduction